Pete, you made a mention in your comments about sprinklers. I thought about in personally and want to put forward the idea that perhaps the lab is not a place for sprinklers, at least in the traditional sense because of the risk of water reactive chemicals. Hypothetically, someone could be working with one of these joyous compounds or an oil when a small fire breaks out. Now a small fire just turned into a big explosion. I googled "laboratory sprinklers" and got nothing of use. Perhaps for the time being, not putting suppression systems in labs is an acceptable risk and one of us should decide to get rich and design a system. I personally don't think halon, CO2, Nitrogen or Dry based systems would be a good idea either because it could add unnecessary risk to those evacuating in addition to putting more random chemicals into a chemical fire. The best long term solution in my opinion would be a water based foam system that is manually activated and included a localized shut off valve this way that scientist can use their better judgment before potentially creating a bigger disaster. The water based foams will put out all class A and B fires while keeping class C in check. The problem I foresee with my thought is that the fire marshals in their infinite wisdom (comment coming from a firefighter) might not approve of a non automated system that can be shut down locally and without cutting a lock. Andrew On Thu, Jun 10, 2010 at 10:45 AM, Secretary ACS DCHASwrote: > From: "Reinhardt, Peter" > Date: June 10, 2010 10:40:25 AM EDT > Subject: RE: [DCHAS-L] US_IL: CHEMICAL FIRE WILL COST SIU $1M > > I must agree with Dan. Looking for someone to blame is unproductive, but > implying that this is an acceptable risk is disgusting. Thankfully, there > were no injuries or loss of life. The costs below do not include loss of > research, loss of research material, loss of data on hard disks down the > hall due to soot, interruption to teaching, research and other activities in > that building, relocation of occupants during recovery and rebuilding, et c. > > > > Higher education has spent the last decade putting sprinklers in all > residence halls. Now we need to do the same for laboratories. (This was a n > unsprinklered lab.) It would be interesting to survey colleges and > universities to see what % of labs are sprinklered. > > > > Pete > > > > Peter A. Reinhardt > Director, Office of Environmental Health & Safety > Yale University > 135 College St., Suite 100 > New Haven, CT =A0 06510-2411 > (203) 737-2123 > peter.reinhardt**At_Symbol_Here**yale.edu > > > > > >
Previous post | Top of Page | Next post